Installing and Winterizing a Sonoma Forge Outdoor Shower
Posted by Corinne Duffey on
A Sonoma Forge WaterBridge shower is not a difficult installation, but it is an unforgiving one: the systems are exposed-pipe, the rough-in dimensions differ by series, and the time to discover a mismatch is before the lines are secured, not after. Everything in this guide comes from Sonoma Forge's own installation guides for the 800, 900, and 1000 series — the same PDFs linked from every WaterBridge product page at Cloud 9.
First, Sonoma Forge's own ground rules
- Professional installation is strongly recommended — that is the manufacturer's wording, in all three guides: "It is strongly recommended that this, and all fixtures, be installed by a professional plumber."
- Work from your model's drawings. Each product page links its spec sheet and the matching series installation guide (800 series wall-mount, 900 series thermostatic, 1000 series floor-mount). Dimensions below are the guides' figures; your model's sheet governs.
- Some state plumbing codes require a remote anti-scald thermostatic mixing valve between the hot supply and the fixture. Per the guides, that valve is installed anywhere between the uninterrupted hot water supply and the fixture and is not included with the shower; the installer sets it, and the guides warn that temperatures above 110 degrees can scald. Ask your plumber early whether your code requires one.
Rough-in by series
800 series — wall-mounted (840, 850, 870, 880)
- Plumbed to 1/2-inch copper lines, stubbed out 8 inches on center; the shower attaches with compression fittings.
- Run the tube through the mounting template and allow at least 2-1/2 inches stubbed out of the finished wall; after uncapping, cut the lines to 1-1/16 to 1-9/16 inches from the finished wall.
- The face of the rain head sits 36 inches from the center of the controls — use that to set mounting height.
- Install additional framing in the wall behind the mounting plate for support.
900 series — wall-mounted thermostatic (940, 950, 970, 980)
- Installed onto 3/4-inch pipe thread; plumb 3/4-inch NPT and secure it in the wall.
- The center-to-center spread is 10-3/4 inches and may vary up to 1/4 inch — Sonoma Forge's instruction is to measure the system you receive before securing supply lines in the wall.
- The face of the rain head is 36 inches from the center of the inlets; add framing behind the mounting bracket for support.
1000 series — floor-mounted (1040, 1050, 1070, 1080)
- Plumbed to 3/4-inch straight nipples, which are included with the system; hot and cold lines 10 inches on center, trimmed exactly 5/8 inch exposed from the finished floor.
- Do not use tapered pipe — only the provided straight-thread nipples.
- Adjustable wall brackets (inner all-thread and outer tube) steady the riser and adjust from 2-1/2 to 7-1/2 inches from the wall; they must be adjusted before installation.
Details installers flag
- The rain head ships with a flow restrictor inside the ball joint. Per the guides: removing it will cause damage — leave it in place.
- Use Teflon tape or joint compound on threads as the guides direct, and support the rain head while tightening its collar.
- On handshower models, make sure the hose hangs without negative tension when not in use; the guides note it will unravel over time if it is left strained.
- When the body is on: turn the water on at the source, check for leaks, and check the volume controls and shut-off valves for proper function — the guides' own final steps.
Winterizing: the manufacturer's rule
Sonoma Forge prints the same sentence in bold in every WaterBridge installation guide: "All exterior plumbing must be drained if freezing temperatures are expected." That is the whole of the manufacturer's winterizing instruction — there is no special procedure and no exemption for mild forecasts. What draining involves on your property depends on how your lines were run, so work through these questions with your plumber before the first freeze:
- Where is the interior shut-off for the shower's supply lines, and does closing it leave any water trapped between the shut-off and the fixture?
- Is there a low point where the lines can be fully drained, and does the handshower hose hold water after the system drains?
- Which outlets should be left open over winter so any residual water has somewhere to go?
In spring the restart is the guides' commissioning sequence in reverse order of concern: water on at the source, check every joint for leaks, and confirm the volume controls and shut-offs work before the first shower of the season.
Care after installation
Per Sonoma Forge: no abrasives — mild soap and water for cleaning, and 100% carnauba wax to protect the finish. Our finishes guide covers how each of the five finishes ages outdoors, and the WaterBridge buying guide compares all sixteen systems if you are still choosing.
Share this post
- Tags: Guides, Installation, Sonoma Forge, WaterBridge